Centralized Control - Via Radio - Aprimatic ADI R230E Instructions

Module commande lampes et appareils electriques génériques
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

11. CENTRALIZED CONTROL - VIA RADIO

A more effi cient way to control more automations simultaneously, using the peculiar characteristics of the modules,
is programming them in order to receive "Centralized Activation" and "Centralized Deactivation" commands. In
this way, you get prioritized centralized commands as well as the possibility to simultaneously control more loads
individually and by group with one remote control.
Centralized commands have priority on local commands: for the entire duration of a centralised command,
local commands will remain disabled.
When a "Centralised Deactivation" command is given, loads will be turned off immediately regardless of their
state and the selected functioning logic.
When a "Centralised Activation" command is given, the connected loads will be turned on immediately. The type
of functioning will depend on the selected functioning logic -i.e. in the "ON/OFF" mode, loads will remain activated
for an indefi nite time, in the timer mode, loads will remain powered up for the pre-set time duration, and in the "dead
man" mode, activation will remain on as long as the signal is transmitted.
Example 1: individual or multiple control of two loads with one 4-key remote control.
Assign the following positions to the radio commands.
Module 1
Assignments
Channel 1 Command
Channel 2 Command
Centralized Activation
Centralized Deactivation Key 4
With these assignments, the transmitter will send the following commands:
Channel 1
Channel 2
Command
Command
Centralized
Centralized
Activation
Deactivation
The easiest way to control more automatic systems via
radio is to store the same remote control in all modules
you wish to operate together. In this case whether
you add a remote control to the system, dedicated to
the simultaneous control or you lose the possibility
to control the automations individually. Additionally,
the commands transmitted by the dedicated remote
control will not have priority.
Key 1
Key 2
Key 3
Example 2: individual or multiple control of 12 loads (C1, C2, ..., C12) with six modules (M1,M2,..,M6) with one
14-key remote control (T1,T2,T3,..,T14).
Assign the following positions to the radio commands.
Radio command
M1
Channel 1 Command
T1
Channel 2 Command
T2
Centralized Activation
T13
Centralized Deactivation
T14
With these assignments, the transmitter will send the following commands:
Keys-Commands confi guration
Command C1
Command C5
Command C9 Command C10 Command C11 Command C12
M2
M3
M4
M5
M6
T3
T5
T7
T9
T11
T4
T6
T8
T10
T12
T13
T13
T13
T13
T13
T14
T14
T14
T14
T14
Command C2
Command C3
Command C4
Command C6
Command C7
Command C8
Centralized
Centralized
Activation
Deactivation