5.3
Activate the LAMP in the PAUSE TIME
During this operation OPENING CONTROL ( START) is possibile to activate the lamp during the pause time.
When the gate is OPEN, it is sufficient to give a PARTIAL OPENING
CONTROL with a device in the terminal board no.24 or from a remote
control. The DEACTIVATION of this function is possibile only repeat-
ing the operation WORKING TIME MEMORIZATION for the OPEN-
ING CONTROL without giving the PARTIAL OPENING CONTROL
from the passages 1 and 2
5.4 Increasing the PAUSE time
The pause time can be increased without having to repeat the times learning operation. While the automation is in pause
mode, each time the push-button P is pressed the pause time is increased by 5 seconds. The level can be increased
four times. The fifth time the push-button is pressed, the pause time returns to the initial value. Therefore, it is possible to
increase the pause time by up to 20 seconds. If 20 seconds is not enough, it is possible to continue increasing the pause
time by performing another opening cycle.
The operation can only be performed when the
automation is in pause mode during opening.
5.5

PASSAGE function

The PASSAGE function, if activated, has the following function:
- OPEN: when the vehicle pass, the gate closes.
- CLOSED: if there is the photo-beam intervention,
the gate reverse when opening ad when the vehicle pass the gate closes.
- In PAUSE TIME the intervention of the photo-beam is 2 seconds after the pause time
To activate or deactivate the PASSAGE make as follow
ACTIVATION:
DEACTIVATION:
5.6
Adjustment of the OBSTACLE DETENCTION
The control unit has an obstacle detection. In case that the gate
has an obstacle , the obstacle detection will stop the motor. It is
possible to adjust the sensitive of the obstacle detection with the
trimmer.
To increase the sensitivity turn in the clock-wise ( the motor will
stop easily) and in the other side to reduce the sensitivity.
WARNING!! The control will not working for the first 2 seconds.
WARNING!! BEFORE ADJUST A LOW SENSITIVITY
BECAUSE A HIGHER CAN STOP THE MOTOR
(for example in case of low temperature or friction)
even if the run hasn't been stopped.
Button P
This is for the activation of the closing photo-beam when
opening or in pause time..
Memorize the working time with START control without
the intervention of the photo-beams.
WARNING! This operation is possibile only when
the PARTIAL OPENING CONTROL is connected
to the terminal board no.24 or to a remote control
Time variation each
time the button is
pressed.
Initial time
For the correct use of the fol-
lowing function you have to
install a couple of photocell as
shown in the paragraph 2.6
Low
sensitivity
The control unit dispose of a jumper JP2 which
can cancel the obstacle detectoin and you can set
up the jumper as follow:
JP2
Activate the obstable
detection
+5"
+5"
+5"
+5"
Led TEST
High
sensitivity
JP2
Exclude the obstacle
detection

Publicité