EN
5.3 - Learning of stroke
The operation must be performed with the rolling shutter
CLOSED. Keep P1 pressed until the DL6 LED flashes
red. Release P1. With the rolling shutter CLOSED, hold
down the P2 button to make the motor move in opening.
Release P2 in the open position. Wait for DL6 to turn
green. Press and hold the P2 button to make the motor
move in closing. Release P2 in the closed position.
5.4 - DIP1 function
AUTOMATIC CLOSURE
If enabled after complete opening, it remains open for a time set with TR1 from 1 Sec
to 120 Sec.
5.5 - DIP2 function
STEP-BY-STEP
With rolling shutter set to OFF
5.6 - DIP3 function
CONDOMINIUM FUNCTION
If set to ON the SBS command only OPENS.
5.7 - DIP4 function
OUTPUT P.OUT 24Vdc
IF SET TO OFF, A 24V LIGHT IS CONNECTED:
- It flashes slowly if the motor is in the opening movement.
- It flashes quickly if the motor is in the closing movement.
- Steady light on if the motor is stopped and not in closing.
IF SET ON ON:
Perform the photocell test
5.8 - DIP5 function
INPUT STOP
If set on OFF ► STOP input (NC)
IF set on ON ► 8K2 edge safety input
5.9 - DIP6 function
OUTPUT FLASH
If set to OFF then the output flashes during motor motion, it switches off approximately
5 sec after the motor is turned off.
If set to ON, the output is activated with the motor and remains active for a time set by
TR2.
22
2 s
3s
FLASHING -
SLOW
RED
P1
P2
NOT ENABLED
STEP-BY-STEP
NOT ENABLED
GATE OPEN LIGHT
FLASHING LIGHT
3s
ON
RED
P2
OFF
ON
ENABLED
OFF
ON
OPEN-CLOSE
OFF
ON
ENABLED
OFF
ON
PHOTO TEST
OFF
ON
STOP
SAFETY
(NC)
(8K2)
OFF
ON
COURTESY
LIGHT
3s