Preliminary Checks; Type Of Installation - Key Automation CT-400 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
Installation
Remember that systems for automatic gates and doors must be installed by highly qualifi ed technicians only and in full
compliance with current law.
Before starting installation, check that the mechanical consistency and sturdiness of the gate or door, check that the
mechanical stops are suitable to stop the movement of the gate or door even if the electrical limit switches should fail or
during manual operations.
1.1

Preliminary checks

Making the correct choice of installation is essential to ensuring adequate safety and good protection against atmospheric
agents. Remember that the control unit contains powered parts and electronic components which by their very nature are
sensitive to infi ltrations and moisture.
The control unit is supplied in a container which guarantees an IP55 protection rating if adequately installed. Install the
control unit on a permanent surface that is perfectly flat, adequately protected against impacts and at least 40 cm off the
ground.
The cables must enter the control unit from the bottom only; we recommend using wire leads and water-tight connections.
When using tubing that could fill up with water or if the tubing comes from an underground well, the wires must enter a fi rst
shunting box placed at the same height as the control unit and then, from there, the wires must be passed into the container
holding the control unit, again entering from the bottom.
This prevents any evaporation of the water in the tubing from forming condensation inside the control unit itself.
1.2
Type of electrical wires
Depending on the installation, the type and number of devices installed, the number of cables needed can vary. The table
below shows the cables needed for a typical installation. The cables used in the installation must be IEC 60335 compliant.
Power supply line
Motor cable (if not equipped)
Flashing signal
Antenna
Key selector
Photocell transmitter
Photocell receiver
1.3

Type of installation

These two simple diagrams show only one of the possible applications for this control unit. The risks inherent to the
"MACHINE" and the user's requirements must be analyzed in depth in order to establish how many elements need to be
installed. All photocells have a system of synchronism that makes it possible to eliminate interference between two pairs
of photocells (for other details, see the instructions for the photocells).
In the diagram, the pair of photocells "Photo A" (considered in this control unit) has no effect during opening while it causes
a total inversion during closing. "Photo A2" is connected in series to "Photo A".
Cable 4x1,5 mm
Cable 4x1,5 mm
Cable 2x1 mm
Shielded cable type RG58
Cable 3x0,5 o 0,75 mm
Cable 2x0,5 o 0,75 mm
Cable 4x0,5 o 0,75 mm
Application on sliding automation
2
2
2
2
2
2
PHOTO A
PHOTO A2

Publicité

Table des Matières
loading

Table des Matières