6
Problems solution
PROBLEM:
The control uniti is powered but:
- The motor doesn't work
- You can hear the drome of the engine and it doesn't work
- The lamp is turn off
- All leds are turn off
SOLUTION:
Check all fuses.
PROBLEM:
The 1,6 A fuse is burnt
SOLUTION:
Check all connections and make sure that are not short-circuits or accessories will consume a lot of power supply
PROBLEM:
The 8 A fuse burns
SOLUTION:
It is possible that the engine is burnt or damaged
PROBLEM:
The motor stops after a few seconds
SOLUTION:
Reduce the sensitive of the motor ( the trimmer is countercloskwise)
PROBLEM:
The control unit doesn't open
SOLUTION:
Check the red led . They should be turn on. If you use the limit switch , the led indicating the closing limit switch close,
when the gate is closed. The green led should be turned off.
PROBLEM:
The control unit doesn't work correctly .
SOLUTION:
Make sure that all services and accessories are connected to the right power supply pole.