2.11 Connection of TURNING ON
17
18
2.12 Connection of the TIMER
17
18
2.13 Connection of the LIGHT
LIGHT 230 Vac
9
11
19
20
21
22
23
19
20
21
22
23
If you prevue to use the photo-
test or the signal light, you cannot
use this connection.
The buttons for the turning on of the control unit should
24
26
be normally open. If more devices are available the
should be serial connected.
In the paragraph 3.1 are described the different fun-
ctions of each control.
Terminal:
If you need a timer it is possible to connect it to the ter-
minal board no. 21 and COM. The contact of the timer
24
26
is normally open and it should be closed for all the time
that the gate is open.
If an opening command is con-
nected to terminal 21, it must be
connected in parallel.
21 OPEN
22 CLOSE
23 START
24 PEDESTRIAN
LIGHT 24 Vac
6
7