The control unit is factory set to allow the selection of several important
functions.
L1
STEP-BY-STEP
Step-by-Step
L2
CODE TX
Code entered
L3
CONDO
L4
MOTOR TIME
Programmed time
L5
PAUSE TIME
With automatic closure
L6
DELAY
L7
AUTOM PRG
LEV MENU
1. STEP-BY-STEP:
n the default configuration the control unit is set with "Automatic"
operating logic enabled (LED n1 off); if the "Step-by-Step" operating logic
is required (LED n1 on), proceed as follows; use the SELECT key to select
blinking LED n1 and then press the SET key: LED n1 becomes steady on
and programming will be completed.
If the "Step-by-Step 1" operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to
obtain the quick blinking of LED. Repeat the procedure if you wish to
restore the previous configuration.
2. TX CODE: (Radio control code):
Up to 120 remotes with different codes of either the fixed or rolling code
type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use the
SELECT key to select blinking LED L2. Press SET once; the LED will
change its blinking mode (longer 1 0 1 0) to show that the
first level is being saved. On sending the selected code with the required
remote, the CODE LED will remain steady on to indicate that programming
has been completed.
To save the code for pedestrian opening / single leaf proceed as follows:
use the SELECT key to select blinking CODE LED L2. Press SET twice
consecutively; the LED will change its blinking mode (1 1 0 1 1 0) to
show that
the pedestrian code is being saved. On sending the selected code with
the required remote, the CODE LED L2 will remain steady on to indicate
that programming will be completed.
To save the code for the 2nd AUX channel proceed as follows: use the
SEL key to select blinking LED L2. Press SET three times consecutively;
the LED will change its blink mode (1 1 1 0 1 1 1 0) to show that the
2nd AUX channel code is being saved. On sending the selected code
with the desired remote, LED L2 will remain steady on to indicate that
programming will be completed.
If all 120 codes have been saved, repeating the programming operation
will cause all the programming LEDs to start blinking to signal that no
further codes can be saved.
Deletion:
Use SEL to go to LED L2; activate blinking of the code to be deleted
(CODE or PEDESTRIAN or 2nd AUX channel as identified by the
associated blinking mode); press and hold down SET for > 5 s. After
this interval the LED will switch off for 2 seconds and the procedure is
completed. If all CODE and PEDESTRIAN codes are deleted, the LED
will remain off.
If only PEDESTRIAN or 2nd CH codes remain stored, the LED blinking
mode will change (1 1 1 1 0 1 1 1 1 0)
Rule of the first saved Remote control:
When programming remotes the following rule is applied: if the first remote
to be saved is of the rolling code type, the receiver will subsequently
accept only rolling code remotes, thus providing enhanced anti-intrusion
security; if the first remote to be saved is of the fixed code type, the
receiver will subsequently accept both fixed code remotes and rolling
code remotes.
3. CONDO:
The Condominium function means that during the opening movement or
during the pause time the control unit will not respond to commands sent
by Pushbuttons or remotes. In contrast, during the closing movement
a command sent by the Pushbuttons or the remotes will reverse the
direction of movement. This operating mode is invaluable when the
automation includes a loop detector.
In the default configuration the control unit is set with the Condominium
Automatic
No code
ON
OFF
30 sec.
Without automatic closure
ON
OFF
ON
OFF
ON
function disabled; if the Condominium function is to be enabled, proceed
as follows: use the SELECT key to select blinking LED L3 and then
press the SET key: LED L3 becomes steady on and programming will
be completed. Repeat the procedure if you wish to restore the previous
configuration.
4. MOTOR TIME (Motor time programming, max 4 minutes):
The control unit is factory set with Operator run time of 30 seconds
without deceleration.
If the motor time of Operators 1 and 2 must be changed, programming
must be carried out with the gate closed as follows: use the SEL key to
select blinking LED L4 and then press the SET key momentarily; Operator
1 will start the opening cycle; when the required deceleration starting
point is reached press the SET key again; LED L4 will start blinking more
slowly and Operator 1 will decelerate; on reaching the required position
press SET to terminate the Opening cycle. At this point LED L4 will revert
to the normal blinking rate Operator 2 will start the opening cycle: repeat
the run time programming operation for Operator 2. When motor times
programming for the opening cycle is terminated Operator 2 restarts
immediately in the closing cycle: repeat the operations described above
for the Closing cycle of Operator 2 followed by Operator 1.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycles have been completed
press the SET key twice consecutively rather than just once.
If the control unit is used in the single operator configuration (dip-switch
SW1 OFF), programming of the run time of Operator 2 is not executed.
During programming, instead of the SET key on the control unit you can
use the button on the remote, providing the remote has been saved
beforehand.
5. PAUSE TIME (Automatic closing time programming 4 min. max.):
The control unit is factory set with automatic closing disabled. If you wish
to enable automatic closing proceed as follows: use the SEL key to select
blinking LED L5 and press the SET key momentarily; now wait for a time
equivalent to the required time; press the SET key again momentarily
and at the same time the automatic closing time will be saved and LED
L5 will remain steady on. If you wish to restore the initial condition (no
automatic closing) select blinking LED L5 and then press the SET key
twice consecutively in an interval of 2 seconds. The LED will switch off
and the operation will be completed.
During programming, instead of the SET key on the control unit you can
use the button on the remote, providing the remote has been saved
beforehand
6. LEAVES DELAY (15 sec. max leaf delay programming):
The control unit is factory set with leaves opening and closing delay
disabled (4 sec.). If the control unit is used in the configuration for an
automation with 2 operators, it may be necessary to set a different leaves
delay time; programming must be performed with the gate closed as
follows: press the SELECT key to select blinking LED L6 then press the
SET key momentarily; now wait for a time equivalent to the desired time
interval and then press the SET key again momentarily, at the same time
the fixed 4 second leaves opening delay and the closing delay for the
programmed time will be saved and LED L6 will remain steady on.
If you want to deactivate this function (without leaves delay), select blinking
LED L6 and then press the SET key twice consecutively in a time interval
of 2 seconds, at the same time the LED will switch off and the operation
will be terminated.
7. AUTOMATIC PROGRAMMING:
The control unit allows Automatic Programming (SIMPLIFIED).
Press the SEL key to select blinking LED L7 and then press the SET key
and hold it down; Operator 2 will perform the closing movement until
reaching the limit switch or end stop, thereafter the Operator 1 movement
will be repeated. If the Operators move in the opposite direction to the
described direction, release the SET key, disconnect the control unit
from the power supply and change the setting of dip-switch SW2 to
change the direction of run of the required operator without having to
rewire the connections. If the Operators sequence is correct, the control
unit completes the Auto programming stage by performing a complete
opening and closing cycle (keep the SET key pressed until the end of the
Auto Programming procedure). During the Auto Programming procedure
the Deceleration cycle is set automatically at approximately 15% of the
complete cycle.
During Automatic Programming, instead of the SET key on the control unit
you can use the button on the remote, providing the remote has been
saved beforehand.