Radio receiver:
Transmitters:
Max TX codes stored in memory: 120 (CODE or PED/2nd CH CODE)
Board dimensions:
PRELIMINARY CHECKS
• Check that the product in the pack is intact and in good condition.
• Check that the place of installation is suitable and in compliance with
the minimum dimensions shown in FIG. 1.
INSTALLATION
• Drill the box in the four corners and then fix the control unit to the wall
(FIG. 2).
• Drill a hole in the underside of the box for the cable inlet. (FIG. 3).
The use of gable glands is recommended.
CONNECTIONS
CN1:
BATT+24V:
Back-up Battery + input
BATT-24V:
Back-up Battery – input
LAMP+24V: 25W Flashing Light + output
LAMP-24V:
25W Flashing Light – output
MOT1+:
Operator 1 + Output.
MOT1-:
Operator 1 – Output.
MOT2+:
Operator 2 + Output.
MOT2-:
Operator 2 – Output.
CN2:
2
nd
CH:
Aux Radio CH Output (Free Contact max load 30V
2
CH:
Aux Radio CH Output (Free Contact max load 30V
nd
FOTO+:
Photocells Control and Power Supply (24 V
FOTO-:
Common GND input.
DS2:
Safety Device 2 Input (NC).
GND:
Common GND input.
DS1:
Safety Device 1 Input (NC).
STOP 8K2:
Emergency Stop Input (NC).
GND:
Common GND input.
P PED:
Pedestrian Pushbutton/Single Leaf/open input (NO).
PP:
Open-close / close command Pushbutton input (NO).
ELS+:
Electric Lock Output 12 V
ELS-:
Electric Lock Output 12 V
24V 5W:
User output (24 V
GND:
Common GND input.
SPIA+24V LED: Indicator light output (+24 V
ANT:
Antenna Ground Input.
ANT+:
Antenna Hot pole Input.
CN3:
ENC1 +:
Operator 1 Encoder Power Input.
ENC1 E:
Operator 1 Encoder Signal Input.
ENC1 GND: Common GND input.
MOT1 FCA:
Operator 1 Opening Limit Switch Input (NC).
MOT1 FCC: Operator 1 Closing Limit Switch Input (NC).
ENC2 +:
Operator 2 Encoder Power Input.
ENC2 E:
Operator 2 Encoder Signal Input.
ENC2 GND: Common GND input.
MOT2 FCA:
Operator 2 Opening Limit Switch Input (NC).
MOT2 FCC: Operator 2 Closing Limit Switch Input (NC).
CN8:
L:
230 V
line input (phase)
N:
230 V
line input (neutral).
FUNCTIONAL CHARACTERISTICS
AUTOMATIC OPERATION:
When either the remote or the low voltage pushbutton panel is used to
control the gate, operation is as follows:
the first command opens the gate until motor time elapses or until the
gate reaches its opening limit position; the second command closes the
gate; if another command is transmitted before motor time has elapsed or
before one of the two limiters has been reached, the control unit reverses
the movement direction during both opening and closing.
STEP-BY-STEP OPERATION:
433 Mhz
18 Bit or Rolling Code
160 x 107 mm.
5W)
15 W (+12V).
15 W (GND).
5W)
4 W)
When either the remote or the low voltage control pushbuttons are used
to control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement. Another command causes the gate to start moving again in
the opposite direction.
Step-by-step 1 operations:
When either the remote or the low voltage control pushbuttons are used
to control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement during both opening and closing. Another command causes
the gate to start moving again in the opposite direction.
AUTOMATIC CLOSING:
The control unit can be set up to close the gate automatically without
sending any additional commands.
The selection of this type of operation is described in Pause time
programming mode.
PEDESTRIAN OPENING:
The control unit allows activation of exclusively Operator 1 for a
programmable time via either the remote or the Pedestrian pushbutton.
SINGLE LEAF:
1A).
Despite being utilized in the configuration for a 2-operator gate, the
1A).
control unit allows the Pedestrian/Single Leaf pushbutton (refer to Menu
2 for the correct pushbutton configuration) to start exclusively Operator
1, in accordance with the times programmed at the time of motor times
programming.
EMERGENCY STOP INPUT:
The control unit allows the connection of an emergency stop pushbutton
(NC). Pressing this pushbutton irrespective of the current operating mode
of the control unit will cause immediate stopping of the gate movement. An
additional gate movement command will be valid provided the emergency
stop input is deactivated and, in any case, the control unit will execute the
gate opening cycle with 5 seconds preflashing.
IMPORTANT: Jumper this input if it is not to be used.
PHOTOCELLS:
Photocells can be powered by and connected to the control unit in
accordance with directive EN 12453.
Input DS1 (NC)
Tripping of the photocells during opening is disregarded, while during
closing it causes reversal of the direction of movement.
Input DS2 (NC)
Tripping during opening causes momentary stopping of the gate; once
the passage is free, the control unit resumes the opening movement.
Tripping during closing causes reversal of the direction of movement.
Programmable input DS3 (NC), see Menu 2.
Tripping during opening causes reversal of the direction of movement.
Tripping during closing is disregarded.
To allow operation in compliance with EN 13849-1 Category 2 a photocell
test is performed before each movement. In order to perform this test it is
essential to power the transmitter of each pair of photocells on the specific
"Photocells Power and Control" output (outputs 3 and 5 of terminal strip
CN2), while the receiver of each pair must be powered via the "Users
Output" (outputs 14 and 15 of terminal board CN2). The control unit
enables the movement only if the test is passed; if it is not, the control unit
inhibits all movements and an alarm condition is signalled by blinking of all
the programming LEDs on transmission of each command.
OPENING AND CLOSING LIMIT SWITCHES:
The control unit allows for the connection of two Opening and Closing
limit switches (NC). Tripping in the associated operating stages causes
immediate stopping of movement for both Operator 1 and 2 outputs.
IMPORTANT: Do not jumper these inputs if they are not used.
COMUNELLO ®Copyright 2014 - All right reserved
23