Compressor Test; Maintenance Intervals - Prebena AEROTAINER 245 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
AEROTAINER 245
To clean the air filter, proceed as follows:

Compressor test

The prototype test was made for this compressor or this is not required if before the commissioning an expert
monitoring is not required. We recommend checking receiver under pressure, depending on the load of
compressor, after 10 operating years, with the assistance of a qualified worker. A qualified worker is compe-
tent to carry out works in accordance with the Regulation on Safety at Work place (formerly - the competent
specialist). Please refer to our authorized partners providing the services. They can provide workers who
have passed the expert examination.
These requirements apply only to the Federal Republic of Germany. The relevant national guide-
lines are applicable for all other countries. The supplied documentation (= documents for admis-
sion) is needed to be kept during the whole period of the receiver life.

Maintenance intervals

Service work
Check oil level and add oil if necessary
Drain the condensate water from the high pressure
receiver
Clean the air filter
General cleaning of compressor
Oil change
Check the operation of reverse pneumatic valve
 Remove the air filter (1) from the connecting thread of the cylin-
der head (2).
 Replace used air filter (1) by a new one.
 With an arm effort tighten the new air filter (1) in the connecting
thread of the cylinder head (2).
Every week
Every month
X
X
Maintenance of compressor
Every 6 month
X
X
X
Every two years
X
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vigon 120Vigon 240Vigon 300Warrior 255Warrior 435

Table des Matières