• Consult a technician if you are not sure how to use or connect the product.
• Maintenance, modifications and repairs must be done by a technician or an
authorized repair centre.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.

Operating elements

1 °C / °F button
2 Blower button
3 + button
4 – button
5 On/off switch – / O
6 LC display
7 Power cord with power plug
LC display (6) with control panel
1
ºC / ºF
*
Operation
Caution, Fire hazard! Keep a safe distance to flammable objects. The temperature
at the hot air outlet is very high.
Warning, risk of burns! Never touch the hot surfaces of the soldering iron. Even after
you have switched off the product, its surfaces remain very hot for some time! Allow
the product to cool before it is stored away.
The supplied stand may have sharp edges due to production factors. So watch for
sharp edges and wear protective gloves when you bend the stand.
• Working on a level, stable, clean, and heat-resistant surface.
• Prepare the stand (14) as a safe place to place down the soldering iron. Bend the stand to
allow you to place down the soldering iron in a safe position. Place the soldering iron with the
safety ring (9) into the opening so that the soldering iron cannot fall.
• Select a nozzle (11, 12, 13) that suits the size of the component you wish to work on and
fasten the nozzle to the hot air outlet (10). Place the soldering iron safely on the stand.
• Plug in the mains plug (7) to a suitable power socket.
• Select the proper solder for the job at hand.
• Set the on/off switch – / O (5) to – to switch on the device. Immediately after turning on, the
heating element begins to heat up and the blower runs. The pre-set temperature (300 °C) is
shown in the LC display (6). The blower levels (1, 2, 3) are displayed as
• Press the + (3) or – (4) button to set the desired temperature. The temperature range may be
set from 200 to 500 ºC in 10 ºC intervals. A high temperature is reached within a short time.
The heating time is approx. 25 seconds to 200 °C and 80 seconds to 500 °C. Determine
whether the temperature is high enough for working by checking both solder and flux.
1
12
ºC / ºF
• If you want to change the blower speed, press the blower button (2). The blower icon
appears on the LC display. Then press the + or – button to set the desired blower level. The
*
blower levels
change according to the setting. The blower icon
Setting
few seconds.
• Press the °C / °F button (1) to change the temperature display from ºC (Celsius) to ºF
(Fahrenheit).
• During brief pauses and when you have finished working, place the soldering iron safely on
the stand.
8 Grip
9 Safety ring
10 Hot air outlet
11 Nozzle Ø 12 mm
12 Nozzle Ø 8 mm
13 Nozzle Ø 5 mm
14 Stand
12
+
-
Setting
1
ºC / ºF
*
ºC / ºF
1
ºC / ºF
*
+
*
-
• As soon as the job is finished, set the on/off switch – / O to O to switch off the soldering iron.
Disconnect the mains plug from the power socket.
• Let the soldering iron cool down sufficiently under supervision before it is stored away.

Care and cleaning

• Before cleaning, let the product cool down sufficiently and disconnect it from the mains.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could
1
damage the casing or cause the product to malfunction.
2
• Use a dry, lint-free cloth to clean the product.
3
4
• Remove any attached nozzle from the soldering iron. Clean any dirty nozzles with a slightly
5
6
damp cloth.
7
Disposal
8
Electronic devices are recyclable waste and must not be disposed of in household
9
waste. Always dispose of the product according to the relevant statutory regulations.
10
You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

11
Input voltage/current ..................... 220 - 240 V/AC, 50 Hz
12
Power consumption ...................... 300 W
Protection class ............................ I
13
Hot air temperature range ............ 200 to 500 ºC
14
Hot air output ................................ max. 22 l/min
Nozzle Ø ....................................... 5 mm, 8 mm, 12 mm
Cable length ................................. approx. 1.2 m
Operating conditions ..................... -6 to +46 ºC, 10 % - 95 % RH
Storage conditions ........................ -20 to +60 ºC, 10 % - 95 % RH
Dimensions (L x Ø) ....................... approx. 30 x 5.6 cm
Weight .......................................... approx. 0.4 kg
12
+
-
.
Setting
1
12
12
+
Setting
-
Setting
goes out after a
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represents the technical status at the time of printing.
Copyright 2017 by Conrad Electronic SE.
+
-
*1521437_v1_0317_02_hk_m_en

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1521437

Table des Matières