7.2 Date of wheel input method for normally dynamic balance mode

1. After the power-on of the machine, it enter the normal balance mode.
2. Input date of rim:
Rotate the measure scale, pull the scale head to inside concave on the edge of the rim, ect figure 7-2.
First LED all off, then display ect figure 7-3.
When scale back to zero position, LED display value is date of rim.
3. When measure values with fact value of rim differ, you need self-calibration of scales then measure again or manual input
date of rim.
4. Input date of rim width: Use manual plastic width measure scale, measure the width value of rim then press b+ or b- key
input date by manual.

7.3 The date input method of ALU-S mode

Normally from normal mode change to other mode, do not need input rim date again, just press ALU key change to you select
mode in directly is fine, only ALU-S mode have special input method, ALU-S mean is special mode, include below two kind
modes (Figure 7-4).
ect figure 7-5 or 7-6, Rotate the measure scale, pull the scale head to inside of the rim(FI) (this position is your select to stick
balance weight on the inside), measure distance (a) and diameter (dI) of inside of the rim, ect figure 7-7, then continue rotate
measure scale, pull the scale head to outside of rim (FE) (this position is your select to stick balance weight on the outside),
measure distance (aE) and diameter (dE) of outside of the rim, ect figure 7-8, enter ALU-S mode.
Fig. 7-2
Fig. 7-4
Fig. 7-5
Fig. 7-3
43
Fig. 7-6

Hide quick links: