Torch Installation Powercut 900/1300/1600 - ESAB PT-37 Manuel D'instruction

Torches d'oxycoupage plasmarc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
SECTION 3
3.3

Torch Installation Powercut 900/1300/1600

1. Open torch lead access door on the front panel of the Powercut-1300/1600.
2. Connect the torch cable male receptacle to the panel receptacle.
Check orientation of the sockets to ensure a correct fit.
Panel Receptacle
Torch Cable Male
Receptacle
3. Connect the air hose to the quick-connect fitting. Place the strain relief in the square cutout in the front of
the console. Line up the groove of the strain relief with the half square cutout area.
Air Hose quick-connect fitting
Torch Lead
Access
Door
20
INSTALLATION
square cutout
strain relief

Publicité

Table des Matières
loading

Table des Matières