STEP 2 AND 3 "DOORS"
Select your car and landing doors. Here you choose the type of door installed (wired or CAN), the allocation of door
opening and closing controls, limit switches, time intervals. The landing door menu lets you choose the distributed
doors by level.
STEP 4 "LEARNING MOTOR"
Motor learning allows a tuning pole to be produced for synchronous motors (gearless or with reducing gears) or auto-
tuning for asynchronous motors to be carried out (with or without encoder).
The type of learning is suggested automatically, according to the "motor type" parameter.
A sequence guides you through all the states to be achieved.
Note: when doing a pole tuning, move the motor manually by opening the brake when the instruction is requested.
Reminder: pôle tuning 1 pour moteur asynchrone gearless
pôle tuning 1 ou 4 pour moteur synchrone gearless
pole tuning 4 for a synchronous winch
auto tuning 3 for with or without encoder asynchronous motor
Remember: After each step, your device will operate in job site control system. You can carry out your work in the
shaft.
STEP 5 "LEARNING LEVELS"
Position learning is offered as soon as the "selection" parameter indicates absolute type counting.
This learning allows the mother board to know the position of the levels accurately.
If the sensor chosen is "Solimax", it must firstly position the device at the bottom and top stops.
Type of pre-configured
pump unit
58