Illustration on the inside of the front
cover
Bring the appliance to working position
- secure it, if required, with parking
brakes.
Ensure that the suction head has been
fitted properly.
Check if the potential equalization cable
is properly connected.
Illustration
Insert the suction hose into the suction
hose connection.
Attach the desired accessories to the
suction hose.
Operation
Illustration on the inside of the front
cover
Insert the mains plug into the socket.
Illustration
Switch the device on at the power
switch
Start suction process.
Cleaning the dust filter
Note: In order to avoid a loss of suction
power, clean the filter at regular intervals.
Illustration
Repeatedly move the handle for filter
cleaning back and forth.
12
Start up
Reading the minimum volume flow
The cleaning time of the pocket filter can be
red on the indicator.
The value depends on the unit perfor-
mance and the suction hose used.
ATTENTION
Clean the pocket filter no later than when
the value is reached. When the value is ex-
ceeded, the air speed in the suction hose
drops below 20 m/s. If the value cannot be
significantly reduced by cleaning, replace
the pocket filter (see "Replacing the pocket
filter").
Power
1,5 kW
3,0 kW
4,0 kW
Clean filter at the specified value.
Empty the collection container
Illustration
Switch off the appliance and remove
the plug from the socket.
Shake off dust filter.
Lower the collection container using the
lever
Empty collection container into disposal
unit.
Dispose of the contents according to
the local provisions.
Note: Move the collection container on the
rollers, not by means of a forklift or crane.
– 3
EN
Hose diame-
Value
ter
DN 50
70mbar/7kPA
DN 50
80mbar/8kPA
DN 50
90mbar/9kPA