Disposal; Disposal Instructions - Wessamat Blue-Line Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Storage container contains water Drain tube of the storage container
Water consumption in water-
cooled machines is too high

8. Disposal

8.1 Disposal instructions

If the machine would be put out of service, please follow the instructions below for disposal:
The refrigerant circuit of the ice cube maker contains HFC and lubricants that are harmful to water!
The machine must therefore be disposed of properly according to the relevant environmental protection
regulations. Should you have no options for proper disposal, please contact your specialist dealer or
WESSAMAT directly.
3. Water level sensor affected by a
'moisture bridge'
4. Fault in water sensor electronics
is kinked or clogged
Flow through cooling water
controller is too high
43
3. Dry the water level sensor
4. Replace water sensor electronics
Ensure free water drainage
Readjust or replace cooling water
controller
E
N
G
L
I
S
C
H
E
N
G
L
I
S
H
A
N
G
L
A
I
S

Publicité

Table des Matières
loading

Table des Matières