Connect AS-i-Bus
Programming instruction for the AS-i
AS-i-Profile: S-1.A.E
The address is defaulted to 0 (HEX). It is
changeable via the bus master or programming
unit. Data bit:
D0:1 Sensor covered
D0:0 Sensor free
D2 and D3 are not used.
Parameter bits (P0 ... P3) are not used.
Test using test magnet
Function
Variants AC and DC-PNP: on testing, the current
state of the electronic switch is reversed.
Variant AS-i: on testing, D0 is inverted.
Warning! Processes may be triggered
accidentally in the system if the switching
state is changed!
½
Make sure that no dangerous processes can
be triggered in the system.
Procedure
½
Hold the test magnet against the mark on the
nameplate:
The switching state changes.
AS-i +
2
1
3
4
AS-i -
1: BN
3: BU
D1:1 State = OK
D1:0 State = error
27