Operating conditions (continued)
Protection degree as
per EN 60529
EMC AC and DC-PNP
EMC AS-i
Storage temperature
Output, general
Switch time
Hysteresis
Dimensions in mm
Connector M12 x 1
3.5**
Ø17,1
*Switch point for vertical installation
**Switch point for horizontal installation
Switch point at: density 1/23 °C/0 bar
22
IP65 with valve plug;
IP65/IP67 with connector M12 x 1
interference emission as per
EN 61326; Equipment Class B
interference immunity as per
EN 61326; Appendix A
(industrial application) and NAMUR
Recommendation NE 21 (EMC)
EN 50295
-40 ... +85 °C
approx. 0.5 seconds on coverage;
approx. 1 second on tuning fork
becoming uncovered
approx. 3 mm for vertical installation
approx. 2 mm for horizontal installation
30
Ø31.5
G
Valve plug
Ø40
Ø31.5
3.5**
Ø17.1
G
40