Before You Start - American Standard Studio ActiVate Right Height 2795.119 Mode D'emploi

Masquer les pouces Voir aussi pour Studio ActiVate Right Height 2795.119:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ROUGHING-IN DIMENSIONS:
NOTE: Distance from wall to closet flange
centerline must be as listed:
Studio
ActiVate
Right Height
Round
®
®
Front 2-piece Toilet Model 2795.119
IMPORTANT: Water supply on the wall is
required at 2-1/4" or 8" from centerline of the
toilet (see rough-in). First suggested position
is hidden behind the toilet. The geometry of
the toilet gives space for this installation. The
second suggested position is next to the toilet.
Between these two positions, the space for the
supply between wall and toilet is limited to
4-1/2". In this case, check your supply and
hose dimensions.
Studio
ActiVate
Right Height
Elongated
®
®
2-piece Toilet Model 2794.119
IMPORTANT: Water supply on the wall is
required at 2-1/4" or 8" from centerline of the
toilet (see rough-in). First suggested position
is hidden behind the toilet. The geometry of
the toilet gives space for this installation. The
second suggested position is next to the toilet.
Between these two positions, the space for the
supply between wall and toilet is limited to
4-1/2". In this case, check your supply and
hose dimensions.

Before You Start:

Turn Off Water Supply
Recommended fitting type for
back-to-back installations.
FINISHED WALL
28-3/16"
(716mm)
8-3/4"
(221mm)
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
16-1/2"
(419mm)
7-1/2"
12-7/8"
(191mm)
(328mm)
12"
C/L OF OUTLET
(305mm)
IMPORTANT: Water supply on the wall is required at 2-1/4" or 8" from centerline of the toilet (see rough-in). First suggested
position is hidden behind the toilet. The geometry of the toilet gives space for this installation. The second suggested position
is next to the toilet. Between these two positions, the space for the supply between wall and toilet is limited to 4-1/2". In this
case, check your supply and hose dimensions.
FINISHED WALL
30-1/4"
(768mm)
8-3/4"
(221mm)
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
18-1/2"
(470mm)
7-1/2"
13-11/16"
(191mm)
(347mm)
12"
C/L OF OUTLET
(305mm)
IMPORTANT: Water supply on the wall is required at 2-1/4" or 8" from centerline of the toilet (see rough-in). First suggested
position is hidden behind the toilet. The geometry of the toilet gives space for this installation. The second suggested position
If Removing An Existing Toilet
is next to the toilet. Between these two positions, the space for the supply between wall and toilet is limited to 4-1/2". In this
case, check your supply and hose dimensions.
Flush to remove
water from tank;
sponge remaining
water from
bowl before
removing toilet.
BACK-TO-BACK INSTALLATION
Depending upon your plumbing and venting conditions, the flow from the toilet in a back-to-back
installation may create a vacuum on the system and draw water from the opposing bowl. The
National Standards Plumbing Code prohibits the use of a cross fitting for drainage as throw over
is possible. The code does approve a directional "Y" style fitting with proper venting to direct the
water downward and away from the other toilet.
- 2 -
15-3/4"
(399mm)
14"
(356mm)
SUPPLY AS
REQUIRED
(position 1 or
position 2)
16-1/2"
2-1/4"
(419mm)
8"
(57mm)
5-1/2"
(204mm)
(140mm)
6"
FINISHED
(152mm)
FLOOR
12-3/16"
(309mm)
15-3/4"
(399mm)
14"
(356mm)
SUPPLY AS
REQUIRED
(position 1 or
position 2)
16-1/2"
2-1/4"
(419mm)
(57mm)
8"
5-1/2"
(204mm)
(140mm)
6"
FINISHED
(152mm)
FLOOR
12-3/16"
(309mm)
Clean Flange
Caution: If leaving floor flange
!
open for more than 1-2 hours,
cover flange to prevent escaping
sewer gases.
30-3/4"
(781mm)
BACK VIEW (for reference)
30-3/4"
(781mm)
BACK VIEW
(for reference)
73 0 2 16 5 - 10 0 Rev. A

Publicité

Table des Matières
loading

Table des Matières