Menus When Connecting The Sd301 To A Se31X/Seh312 - Bosch Rexroth SD301 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
34/144 Bosch Rexroth AG

5 Menus when connecting the SD301 to a SE31x/SEH312

5
Menus when connect-
ing the SD301 to a
SE31x/SEH312
The main menu bar contains the Display,
Process, System Test and System menu
items.
The corresponding menu is called up by
touching one of the menu buttons (Fig. 7).
.
Fig. 7:
The corresponding main menu button will be
displayed inversely as long as the submenu is
visible. If a submenu option has been selec-
ted, then the main menu button has a thicker
border and is thus identified as the active
menu item.
SD301 | 3 609 929 826/06.03
5.1
Display
This menu item contains the Standard, Actu-
al Values 1, Actual Values 2, Graph, and
Graph Memory menu options (Fig. 7).
The Standard, Actual Values 1, and Actual
Values 2 menu options display the following
in the top row of the display field:
– The program number P
– The step number S of the program
– The switch-off criteria and switch-off value
– The quality code QC of the program
– The result evaluation OK/NOK.
5.1.1
Standard
This menu option displays the standard
screen (Fig. 8).
Fig. 8:
The switch-off criterion and the correspond-
ing value are displayed in the upper section
(here: target function torque 34.14 Nm). The
values of all the monitoring functions and the
1)
counter readings
of the OK/NOK counter (if
an OK/NOK counter has been configured)
can be scrolled through in the lower section.
1) Displayed inversely when counting up
reaches the default value or counting
down reaches zero

Publicité

Table des Matières
loading

Table des Matières