42/144 Bosch Rexroth AG
5 Menus when connecting the SD301 to a SE31x/SEH312
5.3.2
Error List
1
2
3
Fig. 29:
The display is divided into:
1 – Consecutive error number
2 – Time
3 – Date
4 – Error code
5 – Error class.
The corresponding error text is listed in the
second section of an error entry.
You can scroll up and down through the error
display by using the arrow keys on the right
side of the screen.
An unacknowledged error is identified by an
inverse display of the error code and error
class (see Fig. 29).
Class 3 errors can be directly acknowledged
via the SD301 by pressing the Acknowl-
edge button. From Version V1.4 onward,
you must log on again before acknowledging
an error.
5.4
This menu item contains the Power On
4
5
Menu, the OK/NOK counter, and SD301
configuration menu options (Fig. 30).
Fig. 30:
SD301 | 3 609 929 826/06.03
System
Settings from the SD301 Config-
uration and Power On Menu can
also be made in BS300 in the
menu System → SE system dis-
play configuration.
The parameterization in the OK/
NOK counter menu option can
also be performed in the BS300
using the System → OK/NOK
counter configuration.