RATING PLATE INFORMATION
EN
- INSTALL AND USE ONLY IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS AND LOCAL
BUILDING CODES. MINIMUM CEILING HEIGHT: 7FT
(2.13M) HEARTH EXTENSION / COMBUSTIBLE FLOOR
PROTECTION: IF INSTALLED ON A COMBUSTIBLE
FLOOR, UNIT MUST BE PLACED ON A
NON-COMBUSTIBLE FLOOR PROTECTOR EXTENDING
6" IN FRONT.
- DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
- REPLACE GLASS WITH ONLY CERAMIC GLASS.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT
POWER BEFORE SERVICING UNIT.
- KEEP VIEWING DOOR TIGHTLY CLOSED DURING
OPERATION.
- CONTACT LOCAL BUILDING AND FIRE OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPEC-
TION IN YOUR LOCAL AREA.
- SUITABLE FOR USE IN MOBILE HOMES WHEN USED
WITH OUTSIDE AIR INSTALLATION KIT.
- REFER TO INSTALLATION INSTRUCTIONS OR LOCAL
BUILDING CODES WHEN PASSING EXHAUST SYSTEM
THROUGH COMBUSTIBLE WALL OR CEILING.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH.
KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
THIS WOOD APPLIANCE NEEDS PERIOD INSPECTION
AND REPAIR FOR PROPER OPERATION. CONSULT
THE OWNER'S MANUAL FOR FURTHER INFORMA-
TION. IT IS AGAINST UNITED STATES FEDERAL
REGULATIONS TO OPERATE THIS WOOD APPLIANCE
IN A MANNER INCONSISTENT WITH THE OPERATING
INSTRUCTIONS IN THE OWNER'S MANUAL.
WOLF STEEL LTD.
24 NAPOLEON ROAD.
BARRIE, ONTARIO L4M 0G8 CANADA
For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
W415-1472 / A / 10.11.16
LISTED PELLET FUEL BURNING ROOM HEATER TESTED TO: ASTM E 1509, UL1482, ULC S628 MODEL NPI45
9700539 (WSL)
MASONRY FIREPLACE INSTALLATION
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
A
BUILT-IN FIREPLACE INSTALLATION
B
B
B
M
M
TOUCH.
RE AWAY.
D INSPECTI
D INSPECTION
ON. CONSULT
N. CONSULT
HER INFORMA-
R INFORMA-
FEDERAL
EDERAL
YE
YEA
YEAR:
OD APPLIANCE
D APPLIA
OPERATING
ATING
MONTH:
U.S. ENVIRONMENTAL PROTECTION AGENCY
U.S. EN
VIR
ONMENTAL PROTECTION AGENCY Certified to comply with 2015 particulate
emissions standards. Not approved for sale after May 15, 2020.
emissions standards. Not approved for sale after May 15, 2020.
MANTEL
B
INSERT
C
HEARTH
H
EXTENSION
EXTENSION
EXTENSION
REPLACE INSTALLATION
REPLACE INSTAL
(FRONT VIEW)
(FRONT VIEW)
(FRONT VIEW)
WOOD MANTEL
WOOD MANTEL
OOD MANT
D
D
D
ENCLOSURE
ENCLOS
E
INSERT
MANUFACTURE DATE: / DATE DE FABRICATION:
2016
2017
2018
1
2
3
4
5
6
Certified to comply with 2015 particulate
40 CFR Part 60, Subpart AAA. 2.4g/hr
40 CFR Part 60, Subpart AAA.
BUILT-IN FIREPLACE INSTALLATION
(SIDE VIEW)
MANTEL
MA
M
G
ENCLOSURE
B
F
E
C
MINIMUM CLEARANCES TO COMBUSTIBLE
Sidewall
A
8"
Mantel
B
8"
Floor Protector
C
6"
Recess Width
D
31 1/2"
Recess Height
E
26 1/2"
Recess Depth
F
16"
Mantel Depth
G
10"
INPUT RATING
MIN
1 LB/HR
MAX
5 LB/HR
ELECTRICAL RATING
120V
3.6A
60HZ
2019
2020
7
8
9
10
11
12
NPI45
2.4g/hr
U.S. Environmental Protecti
vente après le 15 mai, 2020 : 4