ASCENT
LINEAR DIRECT VENT GAS FIREPLACE
TM
BL36-1 PRELIMINARY FRAMING INFORMATION
Product information provided is preliminary and is subject to change without notice. Please consult the
installation manual for the most up to date installation information.
Specifications
Model
BTU (NG)
BL36
16,000
BL36-1
16,000
Framing Dimensions
BL36
53"
134.6cm
MINIMUM FROM BASE
OF APPLIANCE
36"
91.4cm
37 5/8"
95.6cm
Width
BTU (P)
Actual
16,000
35 1/8"
16,000
35 15/16"
14"
[35.6cm] MIN
16 3/8"
41.5cm
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Customer Solutions Department: 1-866-820-8686 • www.napoleonproducts.com
Framing
Actual
37 5/8"
34 1/2"
39 1/16"
36 1/2"
BL36-1
STEEL HEADER
IS REQUIRED
56"
142.2 cm
MINIMUM FROM BASE
OF APPLIANCE
39 3/8"
100cm
36 1/2"
92.7cm
Height
Framing
Actual
36"
16 1/8"
39 3/8"
15 11/16"
[ 35.6cm ] MIN
14"
Depth
Framing
16 3/8"
16 3/8"
COMBUSTIBLE
HEADER
16 3/8"
41.6cm
1