3.0 INSTALLATION PLANNING

READ ENTIRE MANUAL BEFORE YOU INSTALL OR USE THIS APPLIANCE. FAILURE TO FOLLOW THE
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES AND REPLACEMENT PARTS (BLOWERS,
DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENT COMPONENTS, ETC.) COULD RESULT IN A
SAFETY HAZARD AND WILL VOID THE LIMITED LIFETIME WARRANTY.
Check with local building offi cials for any permits required for installation of this pellet appliance and notify your
insurance company before proceeding with installation.
Before installing we recommend placing the appliance outside and load 5 lbs (2.3k) of pellets inside the hop-
per. Plug the appliance in and let it run on HIGH until the pellets run out. This will cure the paint and burn off
most of the oils on the steel, thereby minimizing any smell inside the home.
3.1

APPLIANCE PLACEMENT

Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the
requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 4 feet (1.2m) of the front of the appliance.
3.2

INSTALLATION OPTIONS

NPS45:
To install in a Residential or Mobile Home, see "MOBILE HOME INSTALLATION" section. For alcove instal-
lations, see "ALCOVE INSTALLATION REQUIREMENTS" section. For horizontal vent or vertical vent, see
"VENTING" section. For outside air, see "OUTSIDE AIR" section.
NPI45:
To install as an insert into an existing masonry appliance or factory built appliance, see "VENTING" section.
To install into a combustible enclosure, see "INSTALLATION INTO A COMBUSTIBLE ENCLOSURE" section.
WARNING
!
13
68.1A
67.1B
W415-1472 / A / 10.11.16
EN