Note: Description on cleaning level: When setting the Filter Clean Reminder Function,
timer zone will display 2 digits, of which the former indicates the pollution degree of
operating place and the latter indicates the operating time of indoor unit. There are 4
types of situations:
Cleaning Level
Turn off Clean
Reminder
The former digit shows 1 while the latter one shows 0, which indicates the
accumulating operating time is 5500 hours. Each time the latter digit increases
Slight Pollution
1, the operating time increases 500 hours. When it reaches 9, it means the
operating time is 10000 hours.
The former digit shows 2 while the latter one shows 0, which indicates the
Medium
accumulating operating time is 1400 hours. Each time the latter digit increases
Pollution
1, the operating time increases 400 hours. When it reaches 9, it means the
operating time is 5000 hours.
The former digit shows 3 while the latter one shows 0, which indicates the
accumulating operating time is 100 hours. Each time the latter digit increases 1,
Heavy Pollution
the operating time increases 100 hours. When it reaches 9, it means the
operating time is 1000 hours.
4.13 X-Fan Setting
X-fan Function: If unit is turned off under Cooling or Dry mode, the evaporator of
indoor unit will be dried off automatically to prevent bacteria and mould from gathering.
Turn on X-fan: When unit is on or under Cooling or Dry mode, press FUNCTION
button to select X-fan. "
on this function.
Turn off X-fan: When X-fan function is on, press FUNCTION button to select X-fan.
"
" icon will blink. Then press SWING/ENTER button to turn off this function.
4.14 Out Setting
Out Function: This is used to maintain indoor temperature so that unit can realize
fast heating after it is turned on. This function can only be used under Heating mode.
Turn on Out Function: Under Heating mode, press FUNCTION button to select Out.
"
" icon will blink. Then press SWING/ENTER button to turn on this function.
Turn off Out Function: When this function is on, press FUNCTION button to select
Out. "
" icon will blink. Then press SWING/ENTER button to turn off this function.
4.15 Remote Shield Function
Remote Shield Function: Remote monitor or central controller can disable the
Description of Levels
Timer zone shows 00
" icon will blink. Then press SWING/ENTER button to turn
33
Wired Controller XK79