Set unit of
P16
temperature
Set static
pressure of
P30
indoor fan
motor
High ceiling
P31
installation*
P33
Set Timer
Clock Timer
P34
repetition is
valid
Cooling setting
temperature
P37
under auto
mode
Heating setting
temperature
P38
under auto
mode
Set priority
P43
operation
Clear Filter
P46
Clean
00:Celsius
01:Fahrenheit
01-09: static pressure
level of indoor fan
motor
00: installation height
of standard ceiling
01: installation height
of high ceiling
00: general timer
01: clock timer
00: once
01: repeat everyday
17° C~30° C(63° F~86°
F)
16° C~29° C(61° F~84°
F)
00: normal operation
01: priority operation
00: do not clear
01: clear
19
Wired Controller XK79
00
There are two kinds of static
pressure level:
5 levels: 03, 04, 05, 06, 07
9 levels: 01, 02, 03, 04, 05, 06,
07, 08, 09
Wired controller can be
adapted to the different types
of indoor units that it
possesses 1-9 level selection
05
for setting static pressure.
When the indoor unit with 5
static pressure levels received
the level setting sent by wired
controller is less than 3, it will
be settled as the 3rd level; if it
is over 7, it will be settled as
the 7th level.
Only applicable to cassette
00
units
00
Available only when timer is
00
set to clock timer.
When the temperature unit
25° C(7
is° C, cooling setting
7° F)
temperature minus heating
setting temperature≥1°C.
When the temperature unit
is° F, cooling setting
20° C(6
temperature minus heating
8° F)
setting temperature≥2°F.
When power supply is
insufficient, the indoor units
which are set to priority
00
operation can operate, while
other indoor units are forced to
be turned off.
00