Charge capacity limit
This setting defines how much of the user adjusted capacity the charger will charge into the battery.
This can be useful for partially charging batteries or to prevent overcharge. The range is 10 – 150%
of adjusted capacity.
Safety Timer
This setting defines the maximum amount of time that any of the charger's function can last. This
safety feature can help prevent overcharge or over discharge. The range is 10 – 250 minutes.
Temperature cut-off
This setting adjusts the charge end temperature for batteries (temperature probe available separately).
In some conditions, it can be useful to use this charge mode to obtain optimal charge for NiMh/NiCd
batteries. The range is 10 – 65 degrees Celsius.
Key beep
This setting sets the key beep tone on or off.
Key beep duration
This setting sets the duration of the beep tone when the current task is completed. The settings are
OFF, 5sec, 15sec, 30sec and ON. The tone will stop when the time is over, if the setting is ON then
the tone will continue until you press the ENTER key.
28
By pressing the MENU key, you switch between the function, setting and data view modes. Press
the MENU key so that the data view screen is displayed. The display shows the values for the actual
charge output only.
Use the + and – keys to switch between the different readings.
Battery internal resistance
Battery internal resistance is an indicator of the battery performance. In general, a battery with a
lower value will be more powerful (if tested in the same conditions). You cannot compare batteries
using different chemistries.
Charge end values (from the charge mode)
This screen displays the charge end data. Total charge time, charged capacity and end voltage.
Discharge end values (from the discharge mode)
This screen displays the discharge end data. Total discharge time, discharged capacity and end
voltage.
Cycle end values (if you enter data view from the cycle screen)
This screen displays the cycle end data. charged and discharged capacity. By pressing ENTER and
using the + and – keys you can cycle through the various cycles results. Press MENU to exit.
Team Orion Advantage Twin Spec
www.teamorion.com
Data View
29