Installation/ Assembly

5

Hydraulic connection

The heater is a pressure appliance and it is adjusted mains which pressure should
not exceed 0.6MPa. If the pressure is higher than 0.6MPa, a pressure reducing valve
is to be installed before the safety valve.
A small leak from the safety valve through the outlet pipe may occur. It is a normal
operating state of the appliance. The outlet of the pipe has to remain opened. Do not
clog it, as a clogged outlet may cause a break down of the heater.
The safety valve and the outlet pipe must not be exposed to frost.
Please follow the connection instructions below.
To the inlet fitting of cold water install:
-
T – connection,
-
safety valve, making sure that the direction of the water flow is accordant with
the arrow on the casing of the safety valve,
-
drain valve according to the schematic diagram.
A draining valve allows for emptying the tank. There must never be a cut-off valve
between the safety valve and the tank.
PL;DE;FR;GB;HU;RU-017B_f.761
The heater is to be mounted in the
vertical position.
The C distance over the heater must
be observed in order to perform
maintenance and to exchange the
magnesium anode without taking
the heater off the wall.
After the appliance has been fixed
on the wall, it has to be connected
to the water mains. After filling the
appliance entirely with water and
venting (see start-up section),
connect the heater to the electric
mains. Warranty is void if the
installation is not carried out in
accordance with the instructions.
In order to situate the appliance in
a correct place, one should take
into account that an emergency
leak from the tank will not cause
flooding of the room.