5 Troubleshooting

The motor doesn't work:
Verify:
• The wiring of the motor.
• The power supply specifications.
• The heat generated (wait for the cooling of the motor).
The equipment stops too soon:
Verifiy:
• The operation of end-limits during the rotation of the motor.
• The crown is properly fitted to the tube.
• The end-limits of the motor are properly adjusted.
• That the shade is within the recommended weight limit.
The equipment is noisy:
Verify that:
• The wheel and the crown are well adapted to the used tube.
• The mechanical plays between motor, accessories, tube and end of tube must be
decreased to the maximum.
• The wheel is properly fixed to the tube.
• The equipment is not constrained between the brackets.
• The length of the notch is adapted to the motor hook or to the used crown.
• Debris, screws or other are not in your tube.
• The power supply specifications.
• The temperature of the environment is in conformity with the operating temperature.

6 Technical data

Power supply
Operating temperature
Protection rating

7 Environment

Damaged electric products and batteries should not be disposed of with
normal household waste.
Make sure to drop them in specially provided containers or at an authorized
organization that will ensure they are recycled
8
230V/50Hz - 120V/60Hz - 220V/60Hz -
Copyright © 2011-2017 SOMFY ACTIVITES SA. All rights reserved
110V 50/60Hz
0°C / 60 °C
IP 44