A- PROGRAMMING A NEW MOBILE OR FIXED COMMAND POINT
1-
1- Open the motor's memory from the previously programmed transmitter: Press the PROG key of the transmitter for 3 seconds
—> The motor responds with a "short rotation".
2- Validate the operation from the new transmitter: Press the PROG key of the new transmitter for about 1 second
—> The motor responds with a "short rotation".
- If the new command point is mobile, its range will be equal to that defined in Chapter 14 (page 7). All mobile or wall-mounted
transmitters control the motor according to the command mode selected in Chapter 12 (page 6).
- With respect to a fixed command point, it is the responsibility of the installer to mount this command point where it is visible from the curtain
- To delete a transmitter from the motor memory:perform operation 1- from a transmitter  that was previously programmed and
operation 2- from the transmitter  to be deleted.
B - PARTIAL OPENING
1-
0,5 s.
a-
b-
This function is provided only for MODE 2 (raise by pulse press) and for upward movement.
1- CHECK if the default "partial opening" position is suitable.
A- To do this, position the curtain in the lower position.
b- Press the
STOP KEY FOR 0.5 S.
c- The curtain goes back to its "partial opening" position.
2- CHANGE THE "PARTIAL OPENING" POSITION if the default position is not suitable.
a- For this, position the curtain at the desired "partial opening" position.
b- Press the
STOP key for 6 seconds —> The motor confirms the setting by a "short rotation".
c- The new position of the partial opening is saved.
C- CHANGING THE POSITION OF THE UPPER LIMIT SWITCH
1-
1- Position the motor on the upper hold point adjusted in Chapter 11 (page 5) using the key ▲.
2- Simultaneously press the keys ▲ and ▼ for 6 seconds —> The motor responds with a "short rotation".
3- Position the curtain on the desired limit switch using the keys ▲ and ▼.
4- Press the
STOP key for 3 seconds —> The motor confirms the setting by a "short rotation".
The new limit switch position is saved.
D- CHANGING THE POSITION OF THE LOWER LIMIT SWITCH
1-
1- Position the motor on the lower hold point adjusted in Chapter 11 (page 5) using the key ▲.
2- Simultaneously press the keys ▲ and ▼ for 6 seconds —> The motor responds with a "short rotation".
3- Position the curtain on the desired limit switch using the keys ▲ and ▼.
4- Press the
STOP key for 3 seconds —> The motor confirms the setting by a "short rotation".
The new limit switch position is saved.