Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
3- LIMIT SWITCH SETTINGS
a-
1.
A- Lower hold point
1. Position the motor on the desired lower hold point.
2. Simultaneously press the keys
—> The motor confirms the setting by a "short rotation".
b- Upper hold point
1. Position the motor on the desired upper hold point.The upper hold point must be located at a distance greater than 30 mm from the upper
stop point.
2. Simultaneously press the keys
—> The motor confirms the setting by a "short rotation".
4- VALIDATION OF SETTINGS
3 s.
=
After saving the upper and lower stop points, confirm the settings:
- Press
STOP for 3 seconds.The motor rotates 0.5 second in the downward direction and then automatically rises to force the upper stop
points and "de-compresses".

12- COMMAND MODE

Note that the command mode cannot be changed once the first transmitter is validated in Chapter 13 (page 6).
In this case, a complete reset of the motor is required by performing the instructions in Chapter F (page 9).
- MODE 1: by default, command by press and hold to raise
and lower.
If the configuration of the system allows, you can change
this command mode to MODE 2
- MODE 2: command by pulse press to raise and press and hold to lower.
MODE 2 is authorised only if there is no crushing, shearing, lifting or drawing-in point as defined in EN12453:2001 standard §4.1.1
and §4.1.2.(e.g.: grilles and curtains with projections that may be used to lift a person are not authorised with MODE 2).
Failure to follow these instructions will result in a hazardous situation that could result in death or serious injury. Choosing this
mode engages the full liability of the installer.
CHANGE OF MODE
If the default command mode MODE 1 is appropriate, do not perform this step and skip to the next chapter.
5 s.
If you are not satisfied with this mode or you feel that it poses any danger to people and property, go back to MODE 1
- To go back to MODE 1, simultaneously press the keys
—> The motor confirms the setting by a "short rotation".
13- VALIDATION OF THE FIRST COMMAND POINT
1 s.
2.
STOP and ▲ to set the lower hold point
STOP and ▲ to set the upper hold point
To enter MODE 2:
- Position the curtain outside the limit switch positions.
- Simultaneously press the keys
—> The motor confirms the setting by a "short rotation".
You now control the motor by pulse to raise and by press and hold to lower.
STOP, ▲ and ▼ for 5 seconds
At this stage, you need to validate the 1
- Press the PROG key of the transmitter for 1 second
—> The motor confirms the setting by a "short rotation" .
Your transmitter is now set and controls the motor according to the mode defined in
Chapter 12 (page 6)
b-
1.
MODE 1 (default)
press and hold
inactive
press and hold
STOP, ▲ and ▼ for 5 seconds
command point.
st
X > 30 mm
2.
Do not perform
any control with
the transmitter
when the curtain
is moving.
MODE 2
pulse
STOP / partial opening
press and hold
EN
6/9