Setting the welding parameters
E. Switch off the main switch (2) and disconnect GEOSTAR from the mains. While clamped, screw the lower
contacting system (15) with the lower contacting system setting screw (19) in the direction of the welding
wedge (5) until the lower test strip is touching the welding wedge (5). Then rotate the lower contacting
system setting screw (19) once in the direction of the welding wedge (5) so that the upper contacting
system (14) is pre-tensioned.
F. The lower contacting system setting screw (19) must be locked with the lower contacting system locking
screw (20).
G. Press the locking clamping le-
ver (10) and swing the clamping
lever (7) upwards until the locking
clamping lever (10) engages. Use
your other hand to accomplish this
by holding the automatic welder
firmly by the handle (11). Remove
the test strips. The machine is ready
for use.