Leister GEOSTAR G5 Instructions D'utilisation page 47

Masquer les pouces Voir aussi pour GEOSTAR G5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting the welding parameters
C. Insert test strips (lower and upper membranes) of the material to be welded between the upper and lower drive/
pressure rollers (16/17) and between the upper and lower contacting systems (14/15) and welding wedge (5).
Press the locking clamping lever (10) and close the clamping arm (4) using the clamping lever (7).
Use your other hand to accomplish this by holding the automatic welder fi rmly by the handle (11). Rotate the
welding force adjustment ring (8) until the pressure rollers touch lightly against the material to be welded.
11
14
D. Connect the GEOSTAR to the mains and switch on the main switch (2). Press the locking clamping lever (10)
and swing the clamping lever (7) upwards until the locking clamping lever engages (10). Use your other
hand to accomplish this by holding the automatic welder fi rmly by the handle (11). Rotate the welding force
adjustment ring (8) while open until the welding force on the operating unit (3) matches the desired value
with the clamping arm (4) clamped and the test strip inserted.
3
CAUTION!
Mechanical damage could occur if the maximum welding force of 1500 N is exceeded.
Moving parts may not be touched. The danger exists of inadvertently becoming caught
and being pulled in.
15
11
2
7
8
10
16
17
10
7
5
4
8
4
47