Jotul F 602 CB Installation Et Mode D'emploi page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

US/CAN
Partlist Jøtul F 602 CB
Pos Description .........................................Dim./Spec.
1
Hot plate ........................................... 240 mm
2
Gasket ................................................ LD 360 Ø8.7x850
3
Screw, panhead ............................... M6x12 DIN 7985
4
Air deflector
5
Nut ...................................................... M8
6
Gasket ................................................ LD 187-1 Ø4.8x600
7
Gasket ................................................ V-125 8x150
8
Spring for glass-door ..................... Ø7.6x13
9
Door vent baffle
10
Screw, self thread ............................ M6 x 16
11
Flue outlet
12
Back plate
13
Side panel
14
Rivet ................................................... Ø3x12
15
Rivet ................................................... Ø2,4x4
16
Label
17
Label shield
18
Cover for smoke outlet
19
Countersunk screw ........................ M6x16
20
Baffle plate
21
Air manifold
22
Air chamber, complete
23
Air chamber
24
Screw, collar head ........................... M6x10
25
Screw, collar head ........................... M6x25
26
Rivet ................................................... Ø8x16 mm
27
Knob, wood
28
Screw, filister head ......................... M6x70
29
Nut w/ collar .................................... M6
30
Door catch
31
Door handle
32
Screw, cylinder head ....................... M6x30 DIN 84 S.krom.
33
screw, collar head ............................ M 6x35
34
Insulating blanket .......................... 360x185
35
Burnplate, side, with insulation
36
Burnplate, bottom
37
Insulating blanket .......................... 360x330
38
Screw, hex ......................................... M6x25
39
Washer .............................................. Ø18x06,4x1.6
40 Top plate
41
Pin, door
42
Glass door, complete incl. handle
44
Glass, ceramic .................................. 4x147x154
45
Air slide vent
46
Front plate, complete
47
Front plate
48
Base plate
49
Legs, package of four
50
Leg, 1 pcs
51
Heatshield - bottom
52
Increaser ............................................ Ø 126xØ154 mm
53
Decorative top
54
Casing
55
Washer
56
Washer, black crom.
30
Appendix A:
Alternate floor protection
All floor protection materials must be non-combustible ie. Metal,
brick, stone, mineral fiber boards). Any combustible material may
not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
K-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to r-value;
a.
If r-value is given, no conversion is needed.
b.
If k-value is given with a required thickness (t) in inches:
R=1/k X T.
c.
If c-value is given: R=1/C.
2. Determine the r-value of the proposed alternate floor
protector.
a.
Use the formula in step 1 to convert values not expressed
as "R".
b.
For multiple layers, add r-values of each layer to
determine overall r-value.
3. If the overall R-value of the sustem is greater than the
R-value of the specified floor protector, the alternate is
acceptable.
Example:
The specified floor protector should be 3/4" thick material with a
k-factor of 0.84. The proposed alternate is 4" brick with a c-factor
of 1.25 over 1/8" mineral board witha k-factor of 0.29.
Step A.
Use formula above to convert specifications to
R-value. R=1/k x t= 1/.84 x .75 = .893
Step B.
Calculate r of proposed system.
4" brick of c-1.25, therefore
R brick = 1/c = 1/1.25 = 0.80
1/8" mineral board of K = 0.29 therefore
R mineral board = 1/.29 x 0.125 = 0.431
Total R = R brick + R mineral board= 0.8 + 0.431=1.231
Step C.
Compare proposed system R = 1.231 to specified R of
0.893. Since R is greater than required, the system is
acceptable.
Definitions:
Thermal conductance =
C =
btu
=
(Hr)(ft2)(f)
Thermal conductivity =
K =
btu
=
(Hr)(ft2)(f)
Thermal resistance =
R =
btu
=
(Hr)(ft2)(f)
W
(m2)(k)
W
=
(btu)
(m2)(k)
(hr)(ft)(f)
(m2)(k) =
(btu)(inch)
W
(hr)(ft2)(f)

Publicité

Chapitres

Table des Matières
loading

Table des Matières