ASSEMBLING THE DOSATRON (cont...)
For connecting to polyethylene or
polypropylene pipe :
- Bevel the end of the pipe and slide
on nut (Fig. 2-E) and then ferrule
(Fig. 2-C).
- Slide pipes into water inlet and
outlet (Fig. 2) as far as they will go.
- Push one ferrule (Fig. 2-C) against
the inlet and the other against the
outlet.
- Tighten the nuts (Fig. 2-E).
C
The connection of the DOSATRON to the water network can be done with
flexible hoses (internal diameter 40 mm) to be fixed by means of clamps
and turning adapters ø 40 x 49 mm [1"1/2]. Make sure the water is flowing
according to the direction arrow on the pump body.
The DOSATRON is delivered with a suction hose (cut it to the needed
length) enabling its use with a large capacity concentrate container.
The hose must be fitted with its strainer and weights.
The instructions for fitting the hose are to be found in the specific chapter.
©
DOSATRON INTERNATIONAL / 38
For connecting to PVC pipe :
- Proceed as for the polyethylene and
polypropylene pipes but spread PVC
adhesive on the pipe where the ferru-
les are to be mounted.
- Then place the ferrules over the
pipe using both thumbs in the slot to
widen the ferrule (Fig. 2-C) and
avoid scraping off the adhesive, then
tighten the nut.
NOTE : Wait for one hour before put-
ting into operation.
The ferrule made of polyacetal will
not adhere to the PVC glue and can
therefore be dismantled easily at a
later date.
E
Fig. 2
ASSEMBLING THE DOSATRON (cont...)
NOTE : The maximum suction height is 4 meters (13 vertical feet).
- Fit the hose, equipped with its strainer and its weight, and immerse it in the
solution to be injected.
IMPORTANT ! - Do not put the suction tube strainer on the bottom of the
stock solution container. The strainer must be suspended at least 10 cm
[4"] above the bottom of the tank to avoid sucking up the insoluble parti-
cles that may damage the injection assembly (Fig. 3).
- Do not put the strainer on the ground.
Fig. 3
WHAT YOU MUST NOT DO
Under no circumstance should the solution level be above the water
inlet of the DOSATRON (to avoid siphoning situations).
©
DOSATRON INTERNATIONAL / 39
Fig. 4
WHAT YOU SHOULD DO