3-/4-wire connection (terminals 2/4 and 6/8)
6DR52.. With HART, explosion-protected
6DR53.. Without HART, not explosion-protected
Load voltage at 20 mA
Auxiliary power supply U
● Current consumption I
For connecting to circuits with
the following peak values
Effective inner capacitance C
Effective inner inductance L
Galvanic isolation
7.3.2
Design
Connections, electrical
● Screw terminals
● Cable gland
Connections, pneumatic
SIPART PS2 (6DR5...)
A5E03436620-04, 02/2014
Basic device without
explosion protection
≤ 0.2 V (= 10 Ω)
DC 18 ... 35 V
H
H
-
-
i
-
i
Between U
and I
H
Basic device without
explosion protection
M20x1.5 or
½-14 NPT
Basic device with
explosion protection
Ex d
≤ 0.2 V (= 10 Ω)
DC 18 ... 35 V
(V
- 7.5 V)/2.4 kΩ [mA]
H
-
-
-
Between U
and I
W
H
W
Basic device with
explosion protection
Ex d
2.5 AWG28-12
Ex d certified
M20x1.5;
½-14 NPT or
M25x1.5
Female thread G¼ or ¼-18 NPT
Basic device with
Basic device with
explosion protection
explosion protection
Ex "ia"
Ex "ic", "nA", "t"
≤ 1 V (= 50 Ω)
≤ 1 V (= 50 Ω)
DC 18 ... 30 V
DC 18 ... 30 V
U
= 30 V
"ic":
n
I
= 100 mA
U
i
P
= 1 W
I
i
i
"nA"/"t":
U
I
n
22 nF
22 nF
0.12 mH
0.12 mH
Between U
and I
Between U
H
W
(2 intrinsically safe
circuits)
Basic device with
Basic device with
explosion protection
explosion protection
Ex "ia"
Ex "ic", "nA", "t"
M20x1.5 or
M20x1.5 or
½-14 NPT
½-14 NPT
= 30 V
i
= 100 mA
≤ 30 V
n
≤ 100 mA
and I
H
W
37