CLEANING
AND
MAINTENANCE
PRECAUTION
INSTRUCTIONS
-
IMPORTANT: Before carrying out the
cleaning
and
disconnect the equipment from the mains
power supply:
-
high temperatures can be reached inside
the machine (90°C). After power supply has
been removed, wait until the machine has
reached the room temperature, before
working on it.
-
The machine protection degree is IP21,
therefore it should not be washed with
direct high pressure jets of water.
-
Never leave tools, parts or other loose
material on or in the machine.
-
Before starting machine or cycle, after any
maintenance or repair work, make sure all
protective are correctly installed.
POSSIBLE TROUBLES - CAUSES - SOLUTIONS
PROBLEMS
The machine doesn't catch
The water doesn't go in
Insufficient Washing
Insufficient Rinsing
PREVENTIVE
AND
CLEANING
maintenance
operations,
CAUSES
Main switch is switched off
Water cock closed,
The Overflow is not in its place
Wrong detergent or dosage
Insufficient,
Low temperature in the tank,
Dirty wash filter
Rinsing nozzles blocked,
Hydraulic pressure lower than
1 bar - 100 kPa
CAUTION! FOR ANY OTHER TROUBLE, CALL SERVICE
DAILY MAINTENANCE
-
Disconnect the machine with pushbutton
"A";
ATTENTION!!
-
Disconnect the machine from the
main power supply source by means
of the wall-mounted switch.
-
Lift the overflow pipe and let the water
drain out of the tank;
-
Wash thoroughly the tank and the filter
housing to remove all the impurities;
-
Take the filters and clean them under
running water;
-
Re-assemble the overflow pipe and the
filters in their housings;
-
Check and clean the washing and the
rinsing jets;
-
Clean the outer surface of the machine by
using a wet sponge; don't use water jets
because, besides being dangerous they
could damage the electrical parts; don't
use abrasive detergents;
-
When the machine is to remain idle for a
long time, drain all the water from
boiler and
Also leave the wash tank open.
NEVER WASH THE EXTERNAL PART
THE MACHINE WITH A WATER JET
SOLUTIONS
Turn ON the main switch
Open water cock,
Reassemble the Overflow in its
place
Use anti-foam detergent in the
right dosage and never with
cold water,
Wait untill the water gets hot,
Clean the filter
Unscrew and clean nozzles
under running water,
Wait until the pressure is on or
buy a booster pump
11
from the
electropump.
the
OF