Response time:
PM2.5: ≦ 1 min
VOCs: ≦ 10 min
Humidity: 45% R.H. to 95% R.H. ≦ 1 min
Temperature : 10℃/2 sec.
Sampling rate: 1 sample/second.
Memory data memory capacity: 39 sets. (Direct reading from LCD
Auto data record capacity: Internal micro SD CARD 4GB.
Alarm Output: Open-collect output. Input impedance: 490 Ω
Operating temperature and humidity: 0℃ to 60℃, below 95% R.H.
Storage temperature and humidity: -10℃ to 60℃,below 70% R.H.
Power supply: Four 1.5 V LR-6/AA size batteries, AC adapter
Battery life: Approx. 5.5 hour (LCD backlight ON and DC FAN ON)
Dimensions:
Weight: Approx. 380 g (13.4 oz.)
Accessories: Instruction manual, Battery, PC software, USB
05/24/18 Version No. 00
95% R.H. to 45%R.H. ≦ 3 min
Max. 99 blocks can be split.
Maximum applied Voltage: 24V dc
Maximum drive current: 50 mA dc
165 mm (L) × 93 mm (W) × 75 mm(T), (6.5" L × 3.7" W × 3" T)
connecting cable, AC adaptor DC6V 1000 mA.