USES
The appliance is already arranged both for filtering
and for suction performances.
* In its filtering version (Fig. 1), the air and fumes
conveyed by the appliance are depured both by a
grease filter and by an active coal filter, (to be pur-
chased as accessories) and put again into circula-
tion through the side-grids of the chimney. For this
version an air deflector (to be purchased as acces-
sories) placed on the superior part of the pipe and
allowing air-recycling is necessary (Fig.1).
* In its sucking version (Fig. 2), fumes are direct-
ly conveyed outside, through an evacuation duct
connected with the superior part of the wall or the
ceiling. Both coal filter and air deflector are not ne-
cessary in this case.
INSTALLATION
* Before installing the appliance, in order not to
damage the appliance itself, the metal grease filter
should be removed. Such filter can be removed by
pushing the special filter handle toward the back
side of the cooker hood and turning it downwards
so to unfasten it from its slot (Fig. 3).
Attention: at least two people are needed to
perform the installation.
Before fixing the hood, place the electric feeding
properly into the ornamental pipe and place a hole
for air evacuation in case of a sucking version.
* Suction model
Place the upper plate (Fig. 4.1) on the ceiling. Drill
4 holes, 8 mm each, just next to the slots.
Insert the plastic dowels into the holes (Fig. 4.1-A)
and screw up the plate on the ceiling (Fig. 4.1-B).
Then fasten the lower structure (Fig. 7.2) on the
hood by making its holes and the metric-thread
screws welded on the fan support coincide (Fig.
6.1). Insert the washers and nuts provided (Fig.
6.2-A) and screw with an appropriate tool.
Connect the drainpipe to the power unit nozzle
and fix securely with a hose clamp.
Insert the upper structure (Fig. 6.3) into the lowest
one and adjust its height as required by matching
it with the cooking top's minimum height. Tighten
the two structures securely with the screws provi-
ded (Fig. 6.3-B).
Insert the two extension tubes (Fig. 6.4 & Fig. 6.5)
from above the two structures by making them
come down to the appropriate hood seat. Lift the
hood together with the structure and the extension
tubes to make the four springs (Fig. 6.6-E) hook
to the slots (Fig. 6.3-C). Then tighten the two ele-
ments securely (Fig. 5.1 & Fig. 5.2) with the safety
screws (Fig. 5.2-A) and connect the hood tube to
the drain hole.
Make the electrical connections.
16