15 Commissioning software
15 Commissioning software
As an alternative to service mode, the RLS 45 K
systems can be configured with a special com-
missioning software (for PP 45 and PPB 30
units). The software is suitable for PC systems/
notebooks and can be downloaded at
www.maico-ventilatoren.com.
15.1 System requirements
PC with Internet access (charges may apply). Not
permitted for other operating systems, e.g. for
Mac OS (Mac OS is a trademark of Apple Inc.,
USA).
Minimum PC requirements: Windows Vista® SP2
incl. Microsoft .Net Framework 4.5®, processor
with 1 GHz, 2 GB RAM, 3 GB of free hard disk
space, USB 2.0, LAN-100 MBit/sec. (Windows®
is a trademark of Microsoft Corporation, USA).
15.2 Connecting notebook, loading
software
1. Scan the QR code with your notebook and
load the commissioning software onto your
notebook. Alternatively you can download the
PushPull commissioning software from the
download area at www.maico-ventil-
atoren.com.
2. Take off frame of RLS 45 K.
3. Connect RLS 45 K control with the PC/note-
book (USB).
4. Start commissioning software. Press Estab-
lish connection via USB. The parameters
menu appears.
5. Set parameters according to your system
composition. Save settings.
50
15.3 Commissioning software: Opera-
tion
After the program start the connection is activated
by mouse click. The following standard display
appears:
Left side
• Current operating mode: Heat recovery or
cross-ventilation
• Current ventilation level: Off, ventilation levels
1 to 5, intermittent ventilation or night time
• Faults: Visible when fault is present
Right side
• Query: Shows current system values and sys-
tem statuses for the user.
• Settings: Setting options for the user such as
luminosity of the LEDs, remaining time until fil-
ter change, automatic mode etc.
• Instructions: Information/PDF instructions for
the user