6 Technical data
Sound pressure level:
at distance of 1 m,
free-field conditions
(ventilation levels 1 to
5)
Rated voltage
Power frequency
Volumetric flows for
ventilation levels 1, 2,
3, 4, 5
Power consumption
Permissible ducting
lengths with wired
connection
Weight of complete
slide-in module
Radio components:
Frequency range (in
acc. with
EN 300220-1)
Radio receiver with in-
ternal antenna
"Wireless" operating
distances in the build-
ing are dependent on
the building materials
used:
DS 45 RC → PP 45 RC 30 m
PP 45 EO → PP 45 RC 30 m
PP 45 RC → PP 45 RC 30 m
With PP 45 RC as
amplifier
For more technical data → rating plate.

6.2 Technical data for PPB 30

External diameter
Length of
wall sleeve
Wall thickness
Air filter
Air volume/unit
Degree of protection
38
23 / 28 / 33 / 37 / 40
dB(A)
PP 45 O, PP 45 K: 12 V
PP 45 RC: 230 V
50/60 Hz
15 / 20 / 30 / 36 / 42 m³/
h
1.2 / 1.7 / 2.1 / 2.8 / 3.5
W
From star point, max.
25 m per ventilation unit
3 kg
868.35 MHz
Do not mount on the
wall side of the trans-
mitter
up to:
40 m
DN 160
PP 45 RHK: 500 mm
PP 45 RHL: 800 mm
320 – 790 mm
Filter class ISO 16890
ISO coarse 45 % (G3) 2
items
26 m³/h
IP X4
Sound pressure level:
at distance of 1 m,
free-field conditions
(ventilation levels 1 -
5)
Rated voltage
Power frequency
Volumetric flow in
heat recovery mode,
ventilation levels
1 to 5
Volumetric flow in ex-
haust air mode (no
heat recovery unit)
Power consumption
Degree of heat provi-
sion
SPI
SEC value
Permissible ducting
lengths with wired
connection
Weight of slide-in
module, cpl.
Radio components:
Frequency range (in
acc. with
EN 300220-1)
Radio receiver with in-
ternal antenna
"Wireless" operating
distances in the build-
ing are dependent on
the building materials
used:
DS 45 RC → PP 45 RC 30 m
PP 45 EO → PP 45 RC 30 m
PP 45 RC → PP 45 RC 30 m
With PP 45 RC as
amplifier
For more technical data → rating plate.
18 / 32 / 41 / 45 / 49
dB(A)
PPB 30 O, PPB 30 K:
12 V
PPB 30 RC: 230 V
50/60 Hz
5 / 12 / 18 / 22 / 26 m³/h
45 m³/h
1.7 / 2.5 / 3.4 / 4.4 / 5.3
W
73.3 % (level 3)
0.19 W / (m³/h)
A (-39,71 kWh / (m²*a))
From star point, max.
25 m per ventilation unit
3.6 kg
868.35 MHz
Do not mount on the
wall side of the trans-
mitter
up to:
40 m