Adjustable Pressure Switch Settings 
 
 
 
The adjustable pressure switch, which determines when the heater switches from stand‐by mode to full heat 
mode, is preset at 75 psi (5.2 bar), which is optimum for Propane gas. If you are operating with another LPG 
gas mix, you may want to adjust the pressure to another value. The alternate values are shown on the switch 
from 100% Butane, on the lower end of the scale, approximately 30 psi (2 bar)), to 150 psi (10 bar), on the 
upper  end  of  the  scale.  The  adjustment  can  be  made  by  loosening  the  lock  ring,  turning  the  switch  to  the 
desired pressure setting and re‐tightening the lock ring. Always check to see that only 1 to 1.5 threads are 
visible outside the lock ring as shown in the above pictures. If the switch is 360 degrees (1 full turn) open it will 
not go into stand‐by mode. If the switch is 360 degrees closed it will not allow the heater to reach full heat 
mode. 
26  
 
OUT OF ADJUSTMENT 
Multiple threads exposed: 
Rotate  the  switch  body  clockwise  until 
only one thread is visible outside the lock 
ring and marks are aligned. 
 
OUT OF ADJUSTMENT 
No threads exposed:  
Rotate  switch  body  counterclockwise 
until one thread ring is visible outside the 
lock ring.  
 
 
PROPER ADJUSTMENT 
One exposed thread: 
Pressure setting is factory preset at 75 psi 
(5.2 bar).
ASDI Operations and Maintenance – Second Sun – P/N 52793 
 