1. CRITICAL: Connect the regulator assembly  t o the multi‐valve (on top of the tank) that is connected to the 
vapor  space of the tank, and ensure the regulator is positioned above the vapor space. 
 
2. Connect the high‐pressure  tank line to the upper fitting on  the heater marked "High Pressure Tank 
Connection". 
 
3. Connect the output of the regulator to the lower fitting on the side of the heater cover marked "Low 
Pressure Regulator Connection". 
 
4. In areas with poor gas quality, it is recommended to install a drip leg ahead of the on‐off valve, located 
outside the control cover, marked as "Low Pressure Regulator  Connection". 
 
5. Close the on‐off valve. 
 
6. Open the isolation valve on the Propane tank. 
 
7. Purge the low‐pressure gas line and check the installed plumbing for leaks. 
 
8. Open the heater on‐off valve and check for leaks in the remaining gas train.  
 
9. Repair any leaks before proceeding with the installation. 
 
10. Check both temperature switches for proper contact with the tank surface. 
 
11. Set manifold pressure by inserting a pressure gauge into the Gas Valve pressure port and adjusting the 
pressure using the adjustment screw located under the protective cap on the gas control valve.  See 
Figure 8. 
12  
 
Fig. 8 
ASDI Operations and Maintenance – Second Sun – P/N 52793 
Protective Cap and 
Adjustment Screw 
 