Switching from Propane to LPG
TM
All SECOND SUN
units come from the factory set to operate on Propane fuel. Operation on LPG will require
replacing the installed "P" jet with the "L" jet, attached to the tubing as shown in Figure 11. Replacing the jet
will require ¾" and 11/16" wrenches to loosen and free the primary gas line from the main gas valve to the
manifold shown in Figure 12. Remove the "P" jet from the tubing and replace it with the LPG jet as shown in
Figure 13. Retighten the fitting and restart the unit. No pressure adjustment is required for switching from
Propane to LPG.
Fig. 11 ‐ LPG Jet is located on tubing. It will be
Fig. 12 ‐ Remove tubing to reveal jet in tubing
marked L1 for the SS‐10 or L3 for the SS‐30
Fig. 13 ‐ LPG jet installed in tubing
ASDI Operations and Maintenance – Second Sun – P/N 52793
15