Common Errors / Errores Comunes / Erreurs Communes / Gli Errori Piu Comuni / Häufige Fehler / Veelvoorkomende Fouten - FYTTER runner RU-6X Mode D'emploi

Table des Matières

Publicité

11.
COMMON ERRORS / ERRORES COMUNES / ERREURS COMMUNES / GLI ERRORI PIU COMUNI / HÄUFIGE
FEHLER / VEELVOORKOMENDE FOUTEN
ERRO CODE
NO DISPLAY
NOT DISPLAY ALL
INFORMATION
NOT RUN SMOOTHLY
---OR----
(OR E00/E07)
E01/E13
E02
E03
REASON
A) Electricity not connected.
B) Power switch not turn on.
C) Pcb no power or broken.
D) Signal wire not connected.
E) Computer broken.
F) Background light broken.
A) Display drive IC not inserted well. Re-insert IC,and re-weld it or change
B) EMI gasket slip, not well fastened. Re-assemble screen.
A) driving position has resistance.
B) Running belt too tight or too
loose.
C) Pcb torque too big or too small.
A) Safety key off.
B) Magnetron not fixed well.
A) Signal wire not well connected.
B) Signal wire broken.
C) Signal wire broken.
D) Pcb broken.
A) Motor wire not well connected,
or open circuit.
B) IGBT on pcb broken.
C) Input voltage too low.
A) Speed signal wire not well
connected, or sensor broken.
B) Pcb broken.
HOW TO SOLVE
Connect the electricity.
Turn on power switch.
Press over-load protector or change
new pcb.
Re-connect signal wire or change
new one.
Change new computer.
Check background light wire or
change new one.
new one.
Adjust driving position, or add some
silicon oil.
Adjust the belt tension.
Ajust torque to right position.
Put on safety key.
Fix magnetron to right position.
Re-connect signal wire.
Change new signal wire.
Change new computer.
Change new pcb.
Re-connect motor wire or change
new motor.
Change new pcb.
Stop using, ask electrician to check.
Re-connect speed signal wire or
change new sensor wire.
Change new pcb.
FYTTER |WWW.FYTTER.COM