11.
COMMON ERRORS / ERRORES COMUNES / ERREURS COMMUNES / GLI ERRORI PIU COMUNI /
HÄUFIGE FEHLER / VEELVOORKOMENDE FOUTEN

Error Code

Poor connection between the
E-01
display and controller.
E-02
Over current protection
E-03
Over load protection
E-04
Sudden big current protection
E-05
Explosion proof protection
E-07
Incline checking failure
Reason
Check each joint, change a new line if it is
broken.
Turn off and re-start machine, if still has
problem, need to check motor and pcb if they
are broken
Turn off and re-start machine, if still has
problem, need to check motor and pcb if they
are broken
Check running belt or other place if
something inside, or check pcb if it is burnt.
Check the input voltage is normal or not, or
check pcb burnt or not, or check motor wire
is well connected or not.
Check the AC line in incline motor is well
connected or not, or maybe incline motor
broken, or maybe pcb broken
How to solve
FYTTER |WWW.FYTTER.COM
PAG- 37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ru008r

Table des Matières