INITIAL COMMISSIONING
5.2
Connecting special tool to the pneumatically driven hydraulic unit
You must first install the changeover valve (1) of the pneumatically driven hydraulic unit on the special
tool before connecting the special tool to the pneumatically driven hydraulic unit.
Fig. 9
1. Install the changeover valve (1). See also Chapter 5.2.1 for this.
2. Secure the special tool (2) against moving on a stable worktop.
3. Connect the hydraulic hose lines (3) and (4) to the connections of the hydraulic hand pump (5).
4. Connect the compressed air connection (6) to an external compressed air source. The input air
pressure of the external compressed air system must not exceed 6 bar.
5. Place the two-hand control (7) next to the special tool.
The special tool is ready for use.
®
32