near air currents (near doors, windows, air-conditioning/heating systems, etc.)
exceeding speeds of 0.2 m/sec.
Remove the wooden supports on the bottom (used for transportation) and attach the
adjustable feet (Rif. 5) positioning them so that the unit is horizontal, using a level (Rif.
6) to check the alignment.
Before connecting the unit to the electricity, ensure that the plate data corresponds to
the characteristics of the electrical system to which it is to be connected.
For the unit to function properly, the temperature and relative humidity must not exceed
the limits for climate class 3 (+25°C; R.H. 60%) as established in EN-ISO 23953 - 2
regulations, under which the unit was tested
If the unit is moved, repeat the levelling process, as improper levelling
could compromise the unit's operations.
The unit must be levelled both in the front and in the back.

11.Multiplexing cabinets - specialised technician -

Before multiplexing the units make sure that they are level.
Pos.
1
Multiplexing units bracket
2
Rear riser support
3
Front riser support bracket
4
Handrail alignment pin
5
Nut M6
6
Nut M8
7
Screw TCEI M8x60
8
TCEI M8X120 screw
9
Grain M4x10 EI
10
Washer D 8x17
11
Screw AF TC 3.9x13
12
Screw TCEI M6x20
13
Screw TCEI M6x45
14
Upper plate for joining risers

12.Electrical connection - specialised technician - (Rif. 20)

BEFORE STARTING ANY OPERATION, FIRST DISCONNECT THE SYSTEM FROM
THE POWER SUPPLY!
The systems must be completed in accordance with the regulations that
govern construction, installation, use, and maintenance as envisaged under
the norms in effect in the country where the unit is installed.
ARNEG Spa declines any responsibility with regards to the user and third-
parties for damages caused by breakdowns or malfunctioning of the systems
installed upstream to the unit and for damages caused by the same due to
causes directly attributable to malfunctioning of the electrical system.
The unit must be protected upstream by an automatic omnipolar
thermomagnetic switch with appropriate characteristics. This must also act as
a general line disconnection switch.
Establishment of the electrical power supply line to the point of where it connects to the
unit is the responsibility of the Client. The dimensions of the electrical energy power
supply line must be determined in accordance with the electrical power used by the
unit.
Remove any metal objects worn: rings, watches, bracelets, earrings, etc.
Check the electrical diagrams before carrying out the connection
Check that the voltage supply is as specified on the plate data.
05060088 02 23/07/2012
Name
The electrical system must be earthed!
.
Code
02211300
02360519
02764465
02940652
04230400
04230600
04710042
04711065
04710026
04480112
04705015
04711003
04710028
02764823
Dallas 3
English
35