MOBILE HOME
For mobile home installation, it is mandatory to
• In canada, be connected to a vent system certified according to the standard ULC/ORD-C441 or
CAN/ULC-S609. A chimney meeting the requirements of ULC S629M can also be used.
• In the United States, be connected to a venting system that meets the requirements of UL 641
standard. A chimney that meets the requirements of UL 103 standard may also be used.
• Connect the stove to an outside combustion air source (fresh air).
• The stove must be attached to the structure of the mobile home with two screws. Use the two
anchoring holes located on each side of the pedestal, as shown .
CAUTION : THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND
CEILING / ROOF MUST BE MAINTAINED.
WARNING : DO NOT INSTALL IN A SLEEPING ROOM.
Installation Manual - 3000
Anchoring holes location
Page 21