8 TECHNICAL DATA

Model
Rated power Pnom
P30 min 25°C amb
Pcont 40°C amb
Peak load
Efficiency max./ avg
Nominal input voltage
Input voltage range
Output voltage
Output frequency
Load power factor
No load power draw :
• off mode
• standby scan mode
• low energy mode
• high energy mode
Temperature range
Fan hysterese controlled
Dimensions wxhxd in mm
Weight
Enclosure
DC wire ca.
AC outlet

9 CE DECLARATION OF CONFORMITY

We declare under our sole responsibility that this product is in conformity
with the following standards or standardization documents:
EN 50081-1 Generic 92;
EN 50082-1 Generic 92.
Dr. F.J. ter Heide,
Managing director Mastervolt
EN / Sine wave inverter 12/250 & 24/250 / May 2000
12/250
24/250
230 Volt
117 Volt
250VA, 200W
250VA
200VA
200VA
400VA
400VA
92%
92%
86%
86%
12V DC
24V DC
10-15.5V DC
20-31V DC
230V pure sine
230V pure sine
50 Hz, ± 0.1 Hz
50 Hz, ± 0.1 Hz
all allowed
all allowed
0 mA
0 mA
< 0.5W, 43 mA
< 0.5W, 21 mA
< 3.6W, 350 mA
< 3.6W, 177 mA
< 4.8W, 450 mA
< 4.8W, 200 mA
-20°C till 40°C, derating with 2.5%/°C > 40°C till 80°C ambient
temperature and load controlled
73 x 185 x 120 mm
2.7 kg
IP 20
80 cm, 2.5 mm
2
cable
Europlug M5 + contra plug, 10A / 250V
TECHNICAL DATA
12/250
24/250
230 Volt
117 Volt
250VA, 200W
250VA
200VA
200VA
400VA
400VA
92%
92%
86%
86%
12V DC
24V DC
10-15.5V DC
20-31V DC
117V pure sine
117V pure sine
60 Hz, ± 0.1 Hz
60 Hz, ± 0.1 Hz
all allowed
all allowed
0 mA
0 mA
< 0.5W, 43 mA
< 0.5W, 21 mA
< 3.6W, 350 mA
< 3.6W, 177 mA
< 4.8W, 450 mA
< 4.8W, 200 mA
plug M5
plug M5
(technical changes reserved)