2 Installation checklist

12d
Expansion/wiring centre
12g
eBUS bus coupler
1.2
Wiring diagram 0020180635
1
Heat generator
2
Heat pump
3e
Circulation pump
5
Monovalent domestic hot water cylinder
7i
2-zone module
9b
Zone valve
9k
3-port mixing valve
2
Installation checklist
You must observe all the operating and installation instructions included with the system components.
Work
1
Comply with the conditions for the installation environment
2
Install the heat pump on a wall that has sufficient load-bearing capa-
city
3
Comply with the specified minimum clearances
4
Observe the position of the VRC 700
5
Check the brine circuit for leak-tightness
2
12k
Limit thermostat
12m
Outdoor temperature sensor
12
System control
12a
Remote control unit
12d
Expansion/wiring centre
12g
eBUS bus coupler
12k
Limit thermostat
12m
Outdoor temperature sensor
FS
Flow temperature sensor/swimming pool sensor
Comments/settings
1.
Minimum volume of the installation room 1.60 m³
Environmental temperature 7 °C – 40 °C
2.
3.
Frost-proof
4.
Dry
Weight of the heat pump: 59 kg
For free spaces for maintenance work, see the installa-
tion instructions for the relevant system components
in the living room or main control room
System installation instructions 0020251826_01